Boonton 4500B RF Peak Power Analyzer
Operation
Table 4-15A. Meas > Auto Meas Menu (pulse) (continued)
Menu Item Function
(Type) Selections (SCPI cmd)
AutoMeas Gate Pulse Selects the pulse gating mode
(Mult. Choice)
Choices are:
All Auto measurements based on all pulses in the display
First - Auto measurements based on the first pulse in the display
Markers Automatic pulse measurements based on the first pulse
in the marker interval
Off No automatic pulse measurements are performed (maximizes
acquisition speed)
CALCulate:AMEAsure:MODE { ALL, FRST, MRKRS, OFF }
EdgeDly Mode Pulse Selects the method of measuring the edge delay
from the start of the trace display.
Fig. 4-32a. Meas >
Choices are: Auto Meas
First Edge Edge Delay from the beginning of the trace to the first rising
or falling edge when AutoMeas Gate set to All or First. For
AutoMeas set to Markers, the Edge Delay is from the beginning
of the trace to the first rising or falling edge within the marker interval.
Last Edge Edge Delay from beginning of the trace to the last rising or falling
edge when AutoMeas Gate set to All or First. For AutoMeas Gate
set to Markers, the Edge Delay is from the Beginning of the trace
to the last rising or falling edge within the marker interval.
Burst Edge Delay is the time interval from the first rising or falling edge
to the last rising or falling edge in the trace display when AutoMeas
Gate set to All or First. For AutoMeas set to Markers, the time interval
is from the first rising or falling edge to the last rising or galling edge
within the marker interval.
CALCulate:AMEAsure:EDGEdelay { FRST, LAST, BRST}
Bottom Detect Pulse Enables or disables signal-based IEEE pulse bottom detection.
On, Off
When off, IEEE pulse bottom is forced to 0.0 mW or -99.99 dBm.
On uses automatic bottom detection method described in Section 6.3.
CALCulate:AMEAsure:BOTtom {OFF, ON}